Home - Products
 
 
 
VFM62 Insertion Vortex Flow Meter

VFM62 Insertion Vortex Flow Meter are measurement solution for large pipe line or duct from DN200~DN1000. The flow meter also utilizes the advanced dual sensor and special transmitter technology to provide low flow limit and best anti-vibration performance.


 
 
 
  •  
    Features

    Suitable for large pipeline with known area
    Extremely high sensitivity, minimum flow rate down to 2m/s
    Wider turndown ratio comparing with traditional insertion vortex meters
    Patent dual-sensor design and optimized signal processing technology to ensure best anti-vibration
    No moving parts, very small pressure loss
    Isolated design for electrical parts to eliminate interference
    Wide power source adaptability to fit in different applications
    2 lines LCD display
    Standard output is pulse and 4~20 mA, Hart@4~20mA and RS485 is available
    Metric/British Unit selectable
    Density compensation function available, do not need flow computer for mass flow
    Password protecting function and self-diagnose function

     
     

    High sensitivity, can measure gas/steam down to 2m/s

    High sensitivity sensor, advanced signal processing technology and best anti-vibration features ensures the meter to provide a 1%RD accuracy even at a super low velocity of 2m/s for gas and steam


     
    Applications:
     

    Compressed air measurement
    Vent air measurement.
    HVAC pipeline air measurement
    Measurement of other process gases
    Gas drainage in coal mines
    Measurement of liquids, especially of non-conductive liquids

     
    Accessories:
     
    Remote cable KD9100 Mass Flow Computer Temperature sensor PT100 Pressure transmitter
  •  
    Specifications

    Fluid to measure

    Liquid, low pressure steam, gas

    Nominal diameter

    Insertion:200mm~1000mm(8"~40")

    Measurement range(m/s)

    Low pressure steam 2~70 m/s

    Gas 2~60 m/s

    Liquid 0.3~7m/s

    Accuracy

    2% RD

    Repeatability

    0.3% RD

    Output

    Pulse /4-20mA@ HART / RS-485

    Process Temperature
    Range

    -40℃~150℃

    Process Pressure Limit

    –0.1 MPa (–1 kg/cm2) to flange rating

    Ambient Temperature Range

    –40 to 85°C

    Ambient Humidity

    5 to 100% RH

    Electrical Connection

    1/2 NPT, M20 × 1.5

    Materials

    304 SS, 316 SS, 316L SS

     
    Measurement range of gas and steam
     
    Size
    DN
    Size(inch)
    Inches
    Flow Rate Range
    m3/h
    DN200 8" 226.0~7909.6
    DN250 10" 353.1~12358.8
    DN300 12" 508.5~17796.6
    DN350 14" 692.1~24223.2
    DN400 16" 904.0~31638.4
    DN500 20" 1412.4~49435.0
    DN600 24" 2033.9~71186.4
    DN700 28" 2768.4~96892.7
    DN800 32" 3615.8~126553.7
    DN900 36" 4576.3~160169.5
    DN1000 40" 5649.7~197740.1
         
     
    The flow range above is under 20dge C and 0.1 Mpa, if need standard flow rate under other flow condition , please transfer the velocity range to actual flow rate range, than transfer to standard flow range .
     
  •  
    Model Number
     
    1

    General model

    VFM62-N

    Vortex flowmeter without integral RTD and pressure sensor

    Standard

     

    2

    Transmitter Location

    T

    Integral

    Standard

    The standard remote cable length is 10m, if you required longer cable, please let us know

    R

    Remote

    Option

    3

    Process connection

    0

    Insertion

    Option

    Insertion for DN80~700, wafer and flanged type for pipes smaller than 300mm

    4

    Fluid type

    1

    Liquid

    Standard

    If the fluid is steam, please advise if it is saturated or superheated

    2

    Gas

    Option

    3

    Steam

    Option

    5

    Wetted part material

    1

    OCr18Ni9(304)

    Standard

    For other materials, please advise your speical requirement. Any material will cause a longer production time except 304SS

    2

    316

    Option

    Q

    Other

    Option

    6

    Pressure rating

    3

    1.6

    Standard

     

     

     

    4

    2.5

    Option

    5

    4

    Option

    6

    6.3

    Option

    7

    10

    Option

    8

    16

    Option

    7

    Medium Temperature

    N

    T≤150℃

    Standard

    If the temperature is higher than 350 degree C or lower than 40degree C, please advise us to check if we can do

    8

    Transmitter

    1

    pulse/4~20mA

    Standard

    The HART signal is output though 4~20mA.

    2

    Battery power/pulse

    Option

    3

    pulse/4~20mA@HART

    Option

    9

    Cable grinder

    4

    pulse/RS485

    Option

     

    5

    pulse/RS485 /T&P compensation

    Option

    7

    pulse/4~20mA/T&P compensation

    Option

    N

    M20x1.5

    Standard

    D

    1/2" NPI

    Option

    Q

    Other

    Option

     

     

    Pipe size

    xxx

    xxx

     

    This 3 digits code indicates the inner diameter of the pipe, for example, 050 means DN50, 200 means DN200.


 
 
About Us Application Products Calibration and Test Technical Support
About Us
Calibraion
Quolification
Contact Us
General Application
Compressed Air
Steam Measurement
Gas Drainage
Natural Gas Network
More
Vortex Flowmeter
Thermal Mass Flowmeter
Compressor Online Monitoring System
Compressed Air Evaluation System
Accessories
Calibration Service Configuration Tool
Download
FAQ
 

Address: 2nd floor, Building D2, Hefei Innovation Industrial Park, No.800 Wangjiang West Road,Hefei Tech Development Zone, Hefei, China
Tel: +86 (0551) 63653564
Fax: +86 (0551) 65316075
Skype: comatesales
E-mail: sales@comatemeter.com

     fangliang@comatemeter.com
皖ICP备11006917号-1