TGF600 Thermal Mass Flow Meter

TGF600 Series Thermal Mass Flowmeter is COMATE’s latest thermal mass technology with more rugged design to adapt to harsh industrial applications. It implements COMATE’s latest sensor filming technology and high sensitivity sensors to ensure a stable measurement at very low flow rate down to 0.3Nm/s. The standard insertion model can fit in pipe line from DN80~DN500, extended model can fit in smaller pipe down to DN25 and larger pipe up to DN 6000. The latest TPA600 circuit board and a dual-line LCD display provide user with most powerful and friendly operating interface. The TPA600 technology also ensures the product to give stable and accurate measurement and reliable output.


 
 
 
  •  
    Features

    Insertion installing, can be installed/removed without stopping the line
    Can be used on pipelines in difference shape
    Minimum flow rate down to 0.3m/s, 1:100 super wide turndown ratio
    No moving part, almost no pressure loss
    Direct mass flow measurement, do not require temperature or pressure compensation
    Isolated design for electrical parts to eliminate interference
    Optimized power efficiency design, supper low power consumption down to 60mA@24VDC
    Adapted to any power source
    2 lines LCD display with unit displaying
    Standard output is pulse and RS485, Hart@4~20mA and 4~20mA is available
    Metric/British Unit selectable

    Password protecting function and self-diagnose function
     
    TGF600 Series Thermal Mass Flowmeter measures the gas mass flow base on thermal diffusion theory. It combines COMATE’s advanced technology on transmitter, sensor, filming and calibration, can provide stable and accurate measurement even under harsh industrial applications and require very less maintaining.
     
     

    TGF600 thermal mass flow meter has a no-moving part design, and can measure the mass flow directly. This feature means you can measure the mass flow meter with one single flowmeter, do not need to install any other device such as pressure sensor, secondary instrument etc, save a lot of cost and time. The meter also requires much less maintaining comparing with many other technologies as it has no part to be blocked. Thus it’s a very cost-effective ,reliable and durable measurement solution.

    TGF600 provide 1.5%FS+0.5RD accuracy. The standard turn down ratio is 100:1. We also provide featured turn down ratio down to 10:1 to meet the high accuracy requirement in the range.

     
    Application:
     

    Compressed air measurement
    Pipe line leakage detecting
    Gas drainage in coal mines
    Measurement of other process gas: N2, CO2, O2, Ar, N2O
    Emission monitoring
    Measurement of biogas, aeration etc.

     
    Accessories:
     
    Remote cable PDR80 Portable Date Logger 3/4” Female NPT ball valve in 304SS 3/4” NPT ball valve with flanges in 304SS
       
    Hot tap mounting tool in Al alloy Hot tap hole opener    
  •  
    Specifications
     

     

    Insertion type

    In-line type

    Media Compatibility

    Air, Nitrogen,O2,CO2,Argon,CH4, Natural gas, biogas, and almost all dry and clean air

    Pipe diameter

    DN25~6000mm

    DN15~300mm

    Flow velocity range

    0.3~30Nm/s or 0.6~60Nm/s or 0.9~90Nm/s or 1.2~120Nm/s

    Accuracy

    0.5% RD+ ±1.5% FS

    Temperature of medium

    -40~+150°c

    Pressure of medium

    1.6MPa

    4.0Mpa

    Power supply

    AC85~265V or DC13.5~42V

    Response time

    1 second

    Output

    Frequency + pulse + 4~20Ma as standard

    Communication

    RS~485 as standard , 4~20mA@HART as optional

    Date displayed

    Mass flow, Volume flow in normal condition
    Total flow , Temperature of medium. Velocity

    Ingress protection grade

    IP65 (GB China)

     
    Measurement range
     

    Pipe size (mm)

    Pipe size (inch)

    Option 1 (0.3~30 Nm/s)

    Standard (0.6~60 Nm/s)

    Option 2 (0.9~90 Nm/s)

    Option 3 (1.2~120 Nm/s)

    Min
    (Nm3/hr)

    Max
    (Nm3/hr)

    Min
    (Nm3/hr)

    Max
    (Nm3/hr)

    Min
    (Nm3/hr)

    Max
    (Nm3/hr)

    Min
    (Nm3/hr)

    Max
    (Nm3/hr)

    25 mm

    1“

    0.53

    53

    1.05

    105.9

    1.58

    158.8

    2.11

    211.8

    32 mm

    1 1/4"

    0.87

    86.7

    1.73

    173.5

    2.6

    260.3

    3.47

    347.1

    40 mm

    1 1/2"

    1.36

    135.6

    2.71

    271.1

    4.06

    406.7

    5.42

    542.3

    50 mm

    2"

    2.12

    211.9

    4.23

    423.7

    6.35

    635.5

    8.47

    847.4

    65 mm

    2 1/2"

    3.58

    358.1

    7.1

    716.1

    10.7

    1074.1

    14.3

    1432.2

    80 mm

    3"

    5.42

    542.3

    10.8

    1084.7

    16.2

    1627.1

    21.6

    2169.4

    100 mm

    4"

    8.47

    847.5

    16.9

    1694.9

    25.4

    2542.3

    33.8

    3389.8

    125 mm

    5"

    13.2

    1324.2

    26.4

    2648.3

    39.7

    3972.4

    52.9

    5296.6

    150 mm

    6"

    19.1

    1906.8

    38.1

    3813.5

    57.2

    5720.3

    76.2

    7627.1

    200 mm

    8"

    33.9

    3389.8

    67.7

    6779.6

    101.6

    10169.4

    135.5

    13559.3

    250 mm

    10"

    53

    5296.6

    105.9

    10593.2

    158.8

    15889.8

    211.8

    21186.4

    300 mm

    12"

    76.3

    7627.1

    152.5

    15254.2

    228.8

    22881.3

    305

    30508.4

     
    Nm3/hr means the standard flow rate under 20 degree C, 0.1MPa condition
     
  •  
    Model Number
     

    Model

    Basic Model

    TGF600-

    C

    2

    T

    1

    1

    C

    B

    C

    8

    1

     

    Process Connection

    Flanged in-line

    F

     

     

     

     

     

     

     

     

     

     

    Insertion (NPT)

    C

     

     

     

     

     

     

     

     

     

     

    Insertion (NPT)(with anti-ejection design)

    D

     

     

     

     

     

     

     

     

     

     

    Inertion (with flange)

    G

     

     

     

     

     

     

     

     

     

     

    Probe Length

    290mm (DN25~DN150)

    1

     

     

     

     

     

     

     

     

     

    440mm (DN25~DN500)

    2

     

     

     

     

     

     

     

     

     

    Other

    Q

     

     

     

     

     

     

     

     

     

    Transmitte

    Integral

    T

     

     

     

     

     

     

     

     

    Remote

    R

     

     

     

     

     

     

     

     

    Material

    OCr18Ni9(304)

    1

     

     

     

     

     

     

     

    316

    2

     

     

     

     

     

     

     

    Other

    Q

     

     

     

     

     

     

     

    Pressure Rating

    1.6 Mpa

    1

     

     

     

     

     

     

    2.5 Mpa

    2

     

     

     

     

     

     

    4 Mpa

    3

     

     

     

     

     

     

    6.3 Mpa

    4

     

     

     

     

     

     

    Flange Standard

    For Chemical industry

    A

     

     

     

     

     

    GB China

    B

     

     

     

     

     

    ANSI

    C

     

     

     

     

     

    Other

    Q

     

     

     

     

     

    Max Temperature

    Standard (T≤150℃)

    N

     

     

     

     

    Other

    Q

     

     

     

     

    Enclosure

    Comate blue enclosure

    C

     

     

     

    Transmitte

    pulse/frequency + 4~20mA@HART

    7

     

     

    pulse/frequency + 4~20mA + RS485

    8

     

     

    Power supply

    13.5~42VDC

    1

     

    85~265VAC 50/60Hz

    2

     

    Pipe size

    please use 3 digit pipe size, such as DN50=050, DN300=300

    XXX

    Remark:

    1. Ball valve, Hop-tap insertion tool and hot-tap hole opener are as accessoires, please remark if you need any of them

    2. Please indicate flow rate along with the model number selected

    3. If you have any requirement that can not be fulfilled in this document, please check with us to see the availability

    4. The model selected in 1st line is the standard configuration with no accessories


 
 
About Us Application Products Calibration and Test Technical Support
About Us
Calibraion
Quolification
Contact Us
General Application
Compressed Air
Steam Measurement
Gas Drainage
Natural Gas Network
More
Vortex Flowmeter
Thermal Mass Flowmeter
Compressor Online Monitoring System
Compressed Air Evaluation System
Accessories
Calibration Service Configuration Tool
Download
FAQ
 

Address: 2nd floor, Building D2, Hefei Innovation Industrial Park, No.800 Wangjiang West Road,Hefei Tech Development Zone, Hefei, China
Tel: +86 (0551) 63653564
Fax: +86 (0551) 65316075
Skype: comatesales
E-mail: sales@comatemeter.com

     fangliang@comatemeter.com
皖ICP备11006917号-1