Vortex Flowmeter
Thermal Mass Flow Meter
Compressor Online Monitoring System
Compressed Air Evaluation System
Accessories
|
|
|
VFM45 Vortex Flow Meter(Economical Model) |
VFM45 digital vortex flow meter is a powerful flow meter utilizing “Karman vortex” theory, which can meet the requirement of measuring the flow rate of various fluids such as gas, steam and liquid. The product uses the VFM45 transmitter technology, which provides with the excellent signal processing capability and enhance the vortex metering technology to a new level, which means it has lower measuring limit, better stability and accuracy. The special signal processing method has also ensured a better anti-vibration by eliminating the vibration signals. The VFM45 platform is also an open platform, which means we can keep on upgrading its function according to customer’s unique requirement, and make the product a highly custom-orientation product. |
|
|
|
|
|
|
-
|
Features: |
|
|
Measurement limits down to 5m/s for gas/steam.
No moving parts, very small pressure loss
Isolated design for electrical parts to eliminate interference
Wide power source adaptability to fit in different applications
2 lines LCD display
Standard output is pulse and 4~20mA , Hart@4~20mA and RS485 is available
Metric/British Unit selectable
Density compensation function available, do not need flow computer for mass flow
|
|
VFM45 vortex flowmeter transmitter have been installed over 5000 pcs, provide the most reliable and durable measurement solution. |
Application: |
|
|
. Steam consumption and custody transfer measurement
. Compressed air measurement
. Measurement of other process gases
. Gas drainage in coal mines
. Measurement of liquids, especially of non-conductive liquids |
|
|
|
|
|
Remote cable |
KD9100 Mass Flow Computer |
Temperature sensor PT100 |
Pressure transmitter |
-
Fluid to measure |
Liquid, steam, gas |
Nominal diameter |
Wafer/Flanged(ANSI/DN/DIN/JIS):15mm~300mm(1/2"~12")
Insertion:300mm~700mm(12"~28") |
Measurement range(m/s) |
Liquid 0.5~7 steam or gas 5~70 |
Accuracy |
±1% RD (insertion is 1.5%RD)
Gas or steam:±1.0%RD |
Repeatability |
0.3% RD (insertion is 1.5%RD) |
Output |
4-20mA@ HART / RS-485 |
Process Temperature
Range |
-40℃~280℃ ; -40℃~350℃ ; |
Process Pressure Limit |
–0.1 MPa (–1 kg/cm2) to flange rating |
Ambient Temperature Range |
-40~85℃ |
Ambient Humidity |
5~100%RH |
Electrical Connection |
1/2 NPT, M20 × 1.5 |
Materials |
304 SS, 316 SS, 316L SS |
|
|
|
Flow rate range of gas/steam |
|
|
公称直径
DN |
英寸
Inches |
内径
mm |
流速范围
m/s |
体积流量
Nm3/h |
DN15 |
1/2 " |
16.1 |
10~70 |
6.4~44.5 |
DN20 |
3/4 " |
21.7 |
10~70 |
11.3~79.1 |
DN25 |
1" |
27.3 |
8~70 |
14.1~123.6 |
DN32 |
11/4 " |
36.0 |
8~70 |
23.1~202.5 |
DN40 |
11/2 " |
41.9 |
5~70 |
22.6~316.4 |
DN50 |
2" |
53.1 |
5~70 |
35.3~494.4 |
DN65 |
21/2 " |
68.9 |
5~70 |
59.7~835.5 |
DN80 |
3" |
80.9 |
5~70 |
90.1~1265.5 |
DN100 |
4" |
100.0 |
5~70 |
141.2~1977.4 |
DN125 |
5" |
125.0 |
5~70 |
220.7~3089.7 |
DN150 |
6" |
150.0 |
5~70 |
317.8~4449.2 |
DN200 |
8" |
200.0 |
5~70 |
565~7909.6 |
DN250 |
10" |
250.0 |
5~70 |
882.8~12358.8 |
DN300 |
12" |
300.0 |
5~70 |
1271.2~17796.6 |
|
|
|
|
|
-
1
|
General model
|
VFM45-N
|
Vortex flowmeter without
integral RTD and pressure sensor
|
Standard
|
|
VFM45-M
|
Vortex mass flowmeter
with integral RTD and pressure
sensor
|
Option
|
2
|
Transmitter Location
|
T
|
Integral
|
Standard
|
The standard remote cable length is 10m, if you
required longer cable, please let us know
|
R
|
Remote
|
Option
|
3
|
Process connection
|
0
|
Insertion
|
Option
|
Insertion for DN80~700, wafer and flanged type for
pipes smaller than 300mm
|
1
|
Flanged
|
Standard
|
2
|
Wafer
|
Option
|
3
|
Downsized wafer
|
Option
|
4
|
Fluid type
|
1
|
Liquid
|
Standard
|
If the fluid is steam, please advise if it is saturated or
superheated
|
2
|
Gas
|
Option
|
3
|
Steam
|
Option
|
5
|
Wetted part material
|
1
|
OCr18Ni9(304)
|
Standard
|
For other materials, please advise your speical requirement. Any material will cause a longer
production time except 304SS
|
2
|
316
|
Option
|
Q
|
Other
|
Option
|
6
|
Pressure rating
|
3
|
1.6
|
Standard
|
|
4
|
2.5
|
Option
|
5
|
4
|
Option
|
6
|
6.3
|
Option
|
7
|
10
|
Option
|
8
|
16
|
Option
|
7
|
Medium Temperature
|
N
|
T≤120℃
|
Standard
|
If the temperature is higher than 350 degreeC or lower than 40 degree C, please advise us to
check if we can do
|
S
|
T≤280℃
|
Option
|
H
|
T≤350℃ (wafer or flanged)
|
Option
|
8
|
Transmitter
|
1
|
pulse/4~20mA
|
Standard
|
The HART signal is output though 4~20mA.
|
2
|
Battery power/pulse
|
Option
|
3
|
pulse/4~20mA@HART
|
Option
|
4
|
pulse/RS485
|
Option
|
5
|
pulse/RS485 /T&P compensation
|
Option
|
7
|
pulse/4~20mA/T&P compensation
|
Option
|
9
|
Cable grinder
|
N
|
M20x1.5
|
Standard
|
|
D
|
1/2" NPI
|
Option
|
Q
|
Other
|
Option
|
|
Pipe size
|
xxx
|
xxx
|
|
This 3 digits code indicates the inner diameter of the
pipe, for example, if he pipe is DN50, the code is 050. If the pipe is DN200,
the code is 200
|
|